2398 invalid dss type, 2399 invalid sync type – Quantum Data 801GC User Manual

Page 322

Advertising
background image

8-14

Chapter 8: Error Messages

Model 801GC, 801GF & 801GX¥Rev. A

2398

Invalid DSS type

An invalid digital separate sync type selection exists in the
file.

Reedit the digital separate sync type setting.

2399

Invalid sync type

An invalid sync select exists in the file.

Reedit the sync select setting.

2400

Digital separate sync type selection not
compatible with analog and/or digital sync
type

The generator does not support the given combination of
digital separate sync (H&V) selection with one or both of
the analog or digital composite sync type selections.

Select only one sync type.

2430

Vertical pulse delay extends sync beyond
blanking

The generator does not support vertical sync pulses with
any portion of the pulse occurring outside of the vertical
blanking period.

Decrease the vertical sync pulse width.

Decrease the vertical sync pulse delay.

Increase the vertical period (in lines).

Decrease the vertical active (in lines).

2450

Vertical pulse delay extends sync beyond
blanking

The generator does not support vertical sync pulses with
any portion of the pulse occurring outside of either vertical
blanking period with interlaced operation.

Decrease the vertical sync pulse width.

Decrease the vertical sync pulse delay.

Increase the vertical period (in lines).

Decrease the vertical active (in lines).