Quantum Data 801GC User Manual
Page 228
6-102
Chapter 6: Programming
Model 801GC, 801GF & 801GX¥Rev. A
volts. The <sync 400> factor adjusts the analog sync output level
when ASSS is at 0.400 volts. The <sync 40> factor adjusts the
analog sync output level when ASSS is at 0.040 volts. The <NTSC
714> factor adjusts the NTSC television output level. The <PAL
700> factor adjusts the PAL television output level. The <pclk
700> factor adjusts the pixel clock output (when it is enabled).
Information on the <psync> factors was not available when this
manual was written.
Other Required Cmds:
The AVSC command matches the levels for the three analog
video channels. The ALLU command updates the signal
generating hardware to the new settings and redraws the test
image.
Example:
C A L F 2 0 4 0 2 0 4 5 2 0 5 5 2 0 5 0 2 0 4 6 2 0 4 8
/ / S e t n e w f a c t o r s
A L L U / / U s e n e w f a c t o r s