Quantum Data 801GC User Manual

Page 232

Advertising
background image

6-106

Chapter 6: Programming

Model 801GC, 801GF & 801GX¥Rev. A

CSPP

Composite Sync Pulse Polarity

Classification:

Format parameter setting

Command Syntax:

CSPP <polarity>

Limits:

<polarity>

0 = active-low (negative going pulse)
1 = active-high (positive going pulse)

Query Syntax:

CSPP?

Query Response:

<polarity>

Description:

The CSPP command establishes the logic sense of the digital
composite sync output. The CSPP? query returns the current
setting of CSPP.

Other Required Cmds:

In order to use digital composite sync, it must be gated on with
the CSPG command and selected with the SSST command. The
FMTU command instructs the generator to use the new setting.
The ALLU command updates hardware to the new setting and
redraws the test image.

Example:

C S P G 1 / / E n a b l e d i g c o m p s y n c i n
/ / b u f f e r

C S P P 1 / / S e l e c t a c t i v e h i i n b u f f e r

S S S T 2 / / C h o o s e d i g i t a l c o m p s y n c t y p e

/ / i n b u f f e r

F M T U / / U p d a t e h a r d w a r e t o c u r r e n t

/ / b u f f e r c o n t e n t s

Advertising