6-159

SCAN

SCAN fields per frame

Classification:

Format parameter setting

Command Syntax:

SCAN <fields>

Limits:

<fields>

1 = progressive (non-interlaced)
2 = interlaced

Query Syntax:

SCAN?

Query Response:

<fields>

Description:

The SCAN command establishes the number of fields scanned
per frame. Set to one (1) for progressive (non-interlaced) scan
and two (2) for interlaced scan. The SCAN? query returns the
current setting of SCAN.

Other Required Cmds:

The FMTU command instructs the generator to use the new

setting. The ALLU command updates hardware to the new setting
and redraws the test image.

Example:

S C A N / / S e l e c t i n t e r l a c e i n b u f f e r
F M T U / / U p d a t e h a r d w a r e t o c u r r e n t

/ / b u f f e r c o n t e n t s

SDLY

Sequence step DeLaY

Classification:

Sequence parameter setting

Command Syntax:

SDLY <delay>

Limits:

<delay> Delay time in seconds as a floating point number

min = 0.0 seconds
max = 1.70E38 seconds (infinity for all practical purposes)

Query Syntax:

SDLY?

Query Response:

<delay>

Description:

The SDLY command sets how long a sequence step will pause
before advancing to the next step in the Auto run mode. A
sequence step will use the last value set by the SDLY command.
The SDLY? query returns the current setting of SDLY.

Other Required Cmds:

SMOD setting must be equal to three (3) in order for the SDLY
setting to have any affect on sequence operation.

Example:

S D L Y 5 . 0 / / S e t d e l a y t o f i v e s e c o n d s
/ / p e r s t e p