HSPD

Horizontal Sync Pulse Delay

Classification:

Format parameter setting

Command Syntax:

HSPD <pixels>

Limits:

<pixels>

min = 1
max = HTOT - HRES - HSPW

Query Syntax:

HSPD?

Query Response:

<pixels>

Description:

The HSPD command establishes the delay between the leading

edge of blanking and the leading edge of the horizontal sync
pulse. The HSPD? query returns the current setting of HSPD.

Other Required Cmds:

The FMTU command instructs the generator to use the new

setting. The ALLU command updates hardware to the new setting
and redraws the test image.

Example:

H S P D 1 6 / / S e t 1 6 p i x e l p u l s e d e l a y i n
/ / b u f f e r

F M T U / / U p d a t e h a r d w a r e t o c u r r e n t

/ / b u f f e r c o n t e n t s

HSPG

Horizontal Sync Pulse Gate

Classification:

Format parameter setting

Command Syntax:

HSPG <mode>

Limits:

<mode>

0 = OFF
1 = ON

Query Syntax:

HSPG?

Query Response:

<mode>

Description:

The HSPG command enables and disables the digital horizontal
sync output. The HSPG? query returns the current HSPG mode.

Other Required Cmds:

In order to use digital horizontal sync, digital separate H&V

sync must be selected with the SSST command. The FMTU
command instructs the generator to use the new setting. The
ALLU command updates hardware to the new setting and redraws
the test image.

Example:

H S P G 1 / / E n a b l e H s y n c o u t p u t i n
/ / b u f f e r

F M T U / / U p d a t e h a r d w a r e t o c u r r e n t

/ / b u f f e r c o n t e n t s