Quantum Data 801GC User Manual

Page 213

Advertising
background image

6-87

ALLU

ALL Use

Classification:

Format, Image and Sequence memory management

Command Syntax:

ALLU

Query Syntax:

None

Description:

The ALLU command first checks the current contents of the
format buffer for errors. If no errors are found, it reconfigures
the signal generating hardware in accordance with the contents.
Next, the current test image is re-rendered using the latest system
and format parameter data.

Other Required Cmds:

This command updates the generator after using the FMTL, IMGL
and SEQL commands to load new files from memory. This
command also can be used to see the results of work when
using commands to edit formats or custom images.

Example:

F M T L v g a _ m 3 / / L o a d a f o r m a t f r o m m e m o r y
/ / t o b u f f e r

A L L U / / U p d a t e h a r d w a r e t o c u r r e n t

/ / b u f f e r c o n t e n t s

ASBG

Analog Sync on Blue Gating

Classification:

Format parameter setting

Command Syntax:

ASBG

Limits:

<mode>
0 = OFF
1 = ON

Query Syntax:

ASBG?

Query Response:

<mode>

Description:

The ASBG command enables and disables adding composite sync
to the blue analog video outputs when analog sync is selected
(see SSST command) and an analog video signal is being generated
(see AVST command). The ASBG? query returns the current
setting of ASBG.

S e e t h e A S S G c o m m a n d d e s c r i p t i o n f o r i n f o r m a t i o n o n
simultaneously controlling red, green and blue sync gating.

Other Required Cmds:

The FMTU command instructs the generator to use the new

setting. The ALLU command updates hardware to the new setting
and redraws the test image.

Example:

A S B G 1 / / E n a b l e c o m p s y n c o n b l u e i n
/ / b u f f e r

F M T U / / U p d a t e h a r d w a r e t o c u r r e n t

/ / b u f f e r c o n t e n t s

Advertising
This manual is related to the following products: