Quantum Data 801GC User Manual

Page 250

Advertising
background image

6-124

Chapter 6: Programming

Model 801GC, 801GF & 801GX¥Rev. A

FMTP

ForMaT Path

Classification:

Format memory management

Command Syntax:

FMTP <name>

Limits:

<name> = a valid MS-DOS filename

(8 characters minus any extension)

Query Syntax:

FMTP?

Query Response:

<name>

Description:

The FMTP command sets the current format path name to a
given directory. The query will return the current format path
name.

Other Required Cmds:

None

Example:

F M T P V G A _ F M T S / / F o r m a t s i n V G A _ F M T S d i r
/ / w i l l b e l i s t e d

FMTQ

ForMaT Query pointer

Classification:

Format memory management

Command Syntax:

None

Limits:

<index> = positive integer number

<number> = positive integer number

Query Syntax:

FMTQ? <index> <number>

Query Response:

List of specified format names

Description:

The query returns <number> format names from the list of all
the formats stored in format memory beginning at <index>. The
formats are kept in alphanumeric order.

Other Required Cmds:

None

E x a m p l e s :

F M T Q ? 1 5 / / L i s t t h e f i r s t f i v e i m a g e s

/ / i n m e m o r y

or

F M T Q ? 1 9 9 9 9 / / L i s t a l l i m a g e s i n

/ / m e m o r y

Advertising
This manual is related to the following products: