Quantum Data 801GC User Manual

Page 249

Advertising
background image

6-123

FMTN

ForMaT New

Classification:

Format editor control

Command Syntax:

FMTN [<name>]

Limits:

<name> = a valid MS-DOS filename

(8 characters minus any extension)

Query Syntax:

None

Description:

The FMTN command initializes the format editing buffer. Sending
this one command is equivalent to sending all of the following
commands:

A S B G 0

G A M A 2 . 2

A S C T 1

G A M C 0

A S G G 1

H R A T 0

A S S G 0 , 1 , 0

H R E S 0

A S S S 0 . 2 8 6

H S I Z 2 8 0

A V P G 0

H S P D 0

A V P S 0 . 0

H S P G 1

A V S B 0 . 0

H S P P 0

A V S S 0 . 7 1 4

H S P W 0

A V S T 0

H T O T 0

X V S G 1 , 1 , 1

S C A N 1

C S P G 1

S S S T 1

C S P P 0

U S I Z 2

D C B M 0

V R E S 0

D S E X 0

V S I Z 2 1 0

D S S T 1

V S P D 0

D V S P 0

V S P G 1

D V S T 0

V S P P 0

E Q U A 0

V S P W 0

E Q U B 0

V T O T 0

This should be the first command sent to the generator when
creating a new format. The command only resets to a known
state. The command does not create a usable format.

Other Required Cmds:

None

Example:

F M T N / / I n i t i a l i z e f o r m a t b u f f e r