background image

System Error Codes

Trunk Programming Error Codes

2-16

Strata CIX/CTX Telephone Button Programming 11/04

308

33

FB00

The entered equipment value is invalid.

33

FB03

Wrong assignment intervals.

80

FB00

The designated trunk equipment does not exist in the system.

309

33

FB15

The pause assignment is wrong.

48

FB05 ~

FB10

No incoming destination number is entered for the parameter
required.

49

FB00

The entered DID conflicts with an existing wild card PCB. The
allowable number of DID assignments including a wild card
PCB is exceeded.

49

FB03

The selected GCO conflicts with an existing ILG number.

49

FB04

The selected Pool Line Group conflicts with an existing ILG
number.

51

FB00

The entered ILG number does not exist in the system.

51

FB01

The length of entered DID value exceeds the allowable
contract digit number.

80

FB03

The entered GCO key group does not exist in the system.

82

FB01

The selected ILG number does not exist in the system. The
number of ILGs exceed the system capacity.

96

FB03
FB04

The number of allowable GCO or POOL key group
assignments has been exceeded.

98

FB01

The allowable number of DID assignments has been
exceeded.

310

33

FB00

The entered equipment value is invalid.

48

FB01 ~

FB03

No incoming destination number is assigned for the required
parameter.

80

FB00

The entered circuit is not set to support the designated trunk.

311

49

FB01

Although DISA security is set to Necessary, no DISA code
has been assigned.

312

49

FB01

The entered DID number is not assigned to an ILG.

49

The DID Number entered is invalid.

80

DID Number entered does not exist in the system.

82

FB00

The entered ILG number does not exist in the system.

313

33

FB00

The trunk number entered is out of the range.

33

FB00

The entered equipment value is invalid.

49

FB02
FB03

When Signalling Method field is set to CLASS:

The Signalling Contents field value must be assigned

The CLID Equipment Number Position circuit for the CIU
must be entered.

80

FB00

The entered trunk number does not exist in the system.

Program

Code

Occurred

FB

Sub-

parameter

Error Descriptions