Toshiba STRATA CIX User Manual

Page 84

Advertising
background image

Telephone Button Programming

500 Series Programs

1-80

Strata CIX/CTX Telephone Button Programming 11/04

513-04

Abandoned Call
Record Output

FB04

, n,

Hold

n =

1.

Enable

2.

Disable (default)

Enable record generation for abandoned calls. Incoming SMDR must
be turned on. Abandoned call records will be generated whether or
not incoming SMDR has been set.

513-05

Display Transferred
Call Records

FB05

, n,

Hold

,

Hold

n =

1.

Source (default)

2.

Destination

Select whether to charge a transferred call to the source or
destination party.

514

SMDR for OLG
Assignment

514

,

Hold

This command assigns SMDR parameters for OLGs.

514-00

OLG

n,

Hold

n =

1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)

Specify the OLG for which to set SMDR parameters.

514-01

SMDR Record
Display

FB02

, n,

Hold

n =

1.

Enable (default)

2.

Disable

Enable SMDR Record Display.

514-02

Outgoing Records

FB03

, n,

Hold

,

Hold

n =

1.

Enable (default)

2.

Disable

Enable to generate records for outgoing calls. SMDR Record Display
must be on.

514-03

Outgoing Records

FB03

, n,

Hold

,

Hold

n =

1.

Source (default)

2.

Destination

Enable to apply the SMDR record of a transferred call to its source or
its destination.

515

View BIOU Control
Relay Assignment

515

,

Hold

This assignment is used to view functions of the four control relays on
each BIOU PCB set in Program 105 12 Night Relay and 18 Night Bell
Relay; Program 508 Door Lock Control Assignment; and Program
503 19 BGM Mute Relay. The system allows up to two BIOU PCBs to
provide a total of eight control relays. The control relays can be
configured as an external BGM mute control, Night Bell control, Night
Mode Control, and Door Lock Control.

Notes

BIOU-1 relays are identified as Control Relays 1~4.

BIOU-2 relays are identified as Control Relays 5~8.

515-00

BIOU (1 or 2)

n,

Hold

n =

1 or 2

Enter the BOIU PCB number.

Note

BIOU 1 and BIOU 2 are assigned in Program 100 - Card
Assignment.

515-01

BIOU Relay 1 or 5

FB01

, n,

Hold

n =

1.

Not Use (default)

2.

Ext Paging

3.

Night Bell

4.

Night Relay

5.

Door Lock

View the function of BIOU1, control relay 1 or BIOU2, control relay 5:

View the function of BIOU1, control relay 2 or BIOU2, control relay 6:

View the function of BIOU1, control relay 3 or BIOU2, control relay 7:

View the function of BIOU1, control relay 4 or BIOU2, control relay 8:

NOT USE ñ if the relay is not used.

PAGE MUTE ñ External BGM mute control activates during an
external page (see

ìProgram 503î on page 75

).

NIGHT BELL ñ Night Bell control activates during the system
Night Mode only when incoming CO lines ring (see

ìProgram

102î on page 12

).

NIGHT RELAY ñ Night Mode Control activates continuously
during the system Night Mode (see

ìProgram 105î on page 18

).

DOOR LOCK ñ Door Lock Control activates when a telephone's
Door Unlock button is pressed (see

ìProgram 508î on page 78

).

515-02

BIOU Relay 2 or 6

FB02

, n,

Hold

515-03

BIOU Relay 3 or 7

FB03

, n,

Hold

515-04

BIOU Relay 4 or 8

FB04

, n,

Hold

,

Hold

Table 1-35

Programs 500~577

(continued)

Button

Sequence

Value(s)

Summary

Advertising