Telephone Button Programming

300 Series Programs

1-62

Strata CIX/CTX Telephone Button Programming 11/04

309-11

DNIS VMID Code

FB11

, n,

Hold

n =

Up to 10 digits

Enter the VM mail box number which should answer calls for this DID/
DNIS number.

Note

This code is only sent if using SMDI VM integration in
Program 580, 01. This code will be replaced, after voice mail
answers, by the DTMF code set in Program 309, 15 DID/
DNIS DTMF VMID code - if programmed; therefore, if using
Program 309, 15 code, this VMID code is not necessary.

This mail box number will be sent to voice mail on a DID/DNIS call
that rings directly to voice mail; and, on a direct DID/DNIS call to a DN
that forwards to voice mail before it is answered by the DN.

If a DID/DNIS call is answered by a station and then transferred to a
DN that forwards to voice mail, this mail box number of the DID/DNIS
number or the forwarding DN's mail box number will be sent to voice
mail per Program 579, 01.

If this VMID code is not set, direct DID/DNIS calls will go to the VM
general greeting and DID/DNIS calls that forward from a DN to VM
will go to the DN's VMID mail box.

This Voice Mail box number is added to SMDI packets direct and
forwarded DID\DNIS calls to voice mail as explained above.

309-12

DNIS Name

FB12

, n,

Hold

n =

Up to 16 digits

Enter DNIS name. DNIS names can be assigned from the CTX
WinAdmin (not from programming phones).

309-15

VM Dial

FB15

, n,

Hold

,

Hold

n =

Digits 0~9, * and #. For a
pause enter Px, where
x=0~9 (seconds), up to 10
characters (default = no
value).

Enter the VM mail box number which should answer calls for this DID/
DNIS number.

This mail box number will be sent to voice mail on a DID/DNIS call
that rings directly to voice mail; and, on a direct DID/DNIS call to a DN
that forwards to voice mail before it is answered by the DN.

If a DID/DNIS call is answered by a station and then transferred to a
DN that forwards to voice mail, this mail box number of the DID/DNIS
number or the forwarding DN's mail box number will be sent to voice
mail per Program 579, 01.

If this VMID code is not set, direct DID/DNIS calls will go to the VM
general greeting and DID/DNIS calls that forward from a DN to VM
will go to the DN's VMID mail box. This voice mail box number is sent
to the VM port, as DTMF digits, after the VM port answers a DID/
DNIS call as explained above. These digits are sent to the VM port if
the CTX is set for SMDI or DTMF integration in Program 580, 01.

309-16

Tenant Number

FB16

, n,

Hold

,

Hold

n =

1~8 (default = 1)

Enter the Tenant number to which this DID should be assigned.

310

DIT Assignment

310

,

Hold

This command assigns DIT Number Analysis Table for DIT trunks.
DIT trunks are ground and loop start trunks.

310-00

Line Equipment No.

xxyyzz,

Hold

xx =

Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)

Enter the trunk equipment number. Equipment numbers are required
when assigning a new trunk to the system. It can also be used to
display the equipment location of existing trunks.

Example: If a line should be assigned to an RCOU in cabinet shelf 5,
slot 2, circuit 3, enter 050203.

Cabinet numbers:

CTX100 ñ Select 01 for Base and Expansion cabinet.

CTX670 ñ Select 01 for Base and 02~07 respectively for each
Expansion cabinet.

Slot numbers:

CTX100 ñ Select 01~04 for Base slots and 05~08 for Expansion
slots.

CTX670 ñ Select 01~08 for Base slots and 01~10 for Expansion
slots.

yy =

Slot 01~8 (CTX100),
01~10 (CTX670)

zz =

Circuit 01~24

Table 1-28

Programs 303~315

(continued)

Button

Sequence

Value(s)