Toshiba STRATA CIX User Manual

Page 64

Advertising
background image

Telephone Button Programming

300 Series Programs

1-60

Strata CIX/CTX Telephone Button Programming 11/04

306-18

Network COS

FB18

, n,

Hold

,

Hold

n =

1~32
(default = 1)

Select Network COS number.

307

OLG Delete

307

,

Hold

This command deletes Outgoing Line Groups.

307-00

OLG Number

n,

Hold

,

Hold

n =

1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)

Enter the OLG number to delete.

308

Trunk Timers

308

,

Hold

Assigns trunk timers for analog and T1 trunks.

308-00

Trunk Equipment No.

xxyyzz,

Hold

xx =

Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)

Enter the trunk equipment number.

Note

Equipment numbers are required when assigning a new trunk
to the system. It can also be used to display the equipment
location of existing trunks.

yy =

Slot 01~8 (CTX100),
01~10 (CTX670)

zz =

Circuit 01~24

308-01

Auto Release

FB01

, n,

Hold

,

n =

1.

Disable

2.

Detect 95ms

3.

Detect 450ms

(default)

Select the Automatic Release timing.

Note

Select Disable if the CO does not send the automatic release
signal to the loop start trunk.

308-02

Short Flash

FB02

, n,

Hold

,

n =

0~15, where 1 = 100msec.
(default = 5, which is .5
seconds)

0 = no flash

Select Short Flash Time. When a telephone initiates the short flash
signal to the CO line it is connected to (using the short Flash feature
button or access code #450) the duration of a short flash is
determined by this command. Normally this signal is used to hook
flash a centrex line. The short flash range is 0 to 1.5 seconds in
increments of 0.1 seconds.

308-03

Long Flash

FB03

, n,

Hold

n =

0, 5, 10, 15, 20, 25 and 30,
where 5 = .5 seconds.
(default = 20)

Select Long Flash Time. When a telephone initiates the long flash
signal to the CO line it is connected to (using the Long Flash feature
button or access code #451) the duration of a long flash is determined
by this command. Normally this signal is used to disconnect the line.
The long flash range is 0 to 3 seconds in increments of 0.5 seconds.

308-04

Pause after Flash

FB04

, n,

Hold

n =

0~5, 0 = immediately sent,
and 1sec.delay to
5sec.delay

(default = 1 second delay
before sending digits)

Pause time after flash: After a flash signal is sent to a CO line, this
timer determines when the line will start to send the dialed digits to
the other end.

308-04

Response Timer

FB05

, n,

Hold

n =

0~3000

The response timer is for analog DID/TIE lines that have the ìstart
methodî set for ìTimingî in Program 300-06. After a line is seized this
timer determines when the line will start to send the dialed digits to
the other end.

Possible Values 0=immediatly sent, and 50msec.delay to
500msec.delay. (default=500mseconds delay before sending digits).

309

Direct Inward Dialing

309

,

Hold

This command assigns DID Number Analysis Table to ILG.

309-00

ILG Number

n,

Hold,

n =

1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)

Select the ILG number.

309-01

DID Number

FB01

, n,

Hold

n =

1~7 digits may include wild
card м?о where м?о = 0~9

Enter a DID number.

Table 1-28

Programs 303~315

(continued)

Button

Sequence

Value(s)

Summary