Telephone Button Programming

500 Series Programs

Strata CIX/CTX Telephone Button Programming 11/04

1-75

T

e

le

phon

e Butt

on

Pr
og
ramm

ing

502-17

All Page Group

FB17

, n,

Hold

n =

1.

On

2.

Off

(default)

Enter this station in all Paging Groups.

502-18

All Emergency Page
Group

FB18

, n,

Hold

,

Hold

n =

1.

On

2.

Off

(default)

Enter this station in all Emergency Paging Groups.

503

Paging Devices
Group Assignment

503

,

Hold

Assigns BIOU Page Zone Relays to Page Groups.

503-00

Zone Relay Number

n,

Hold

n =

1~8

BIOU1 = 1~4

BIOU2 = 5~8

Select the BIOU Page Zone relay that should be assigned to the Page
Groups below. This relay activates whenever the selected Page
Group is paged.

BIOU1 = Zone Relays 1~4.

BIOU2 = Zone Relays 5~8.

503-
01~16

PG01~PG16

FB01

~

FB16

, n,

Hold

n =

1.

On

2.

Off (default)

Turn on if the selected BIOU Page Zone Relay should activate with
this Page Group.

503-17

All Page Group

FB17

, n,

Hold

n =

1.

On

2.

Off (default)

503-18

All Emergency Page
Group

FB18

, n,

Hold

n =

1.

On

2.

Off (default)

503-19

BGM Mute Relay

FB19

, n,

Hold

,

Hold

n =

0~8 (default = 0)

BIOU1 = 1~4

BIOU2 = 5~8

Assign BIOU generic relay as the BGM mute relay. This relay
activates whenever the external page is in use

BIOU1 = Generic Relays 1~4.

BIOU2 = Generic Relays 5~8.

Note

The CTX100 ACTU built-in relay is programmed as relay 5.
For this relay operation,BIOU2 is installed, as default, in a
virtual equipment position - Cabinet 2, Slot 5, PCB code 20,
in Program 100. To install an actual BIOU2 and disable the
ACTU built-in relay, use the programming telephone to
remove the virtual BIOU2 and then install the actual BIOU2 in
Cabinet 01 Slot 01~08 in the normal manner.

504

System Call Forward
Operation Status

504

,

Hold

This command assigns System Call Forward Type for the pattern.

504-00

SCF Number

n,

Hold

n =

1~4 (CTX100)
1~10 (CTX670 Basic)
1~32 (CTX670 Exp.)

Select the SCF pattern number to configure.

504-01

Telephone Status

FB01

, n,

Hold

,

Hold

n =

1.

No Data

(default)

2.

Busy

3.

No Ans

4.

Busy No Ans

5.

DND

Select the status or state in which the telephone should be for this
system call forward pattern to activate.

Notes

Each 500-01 call type must be the same telephone status. Also,
all calls must be the same Call Forward type.

Telephone status must be the same as telephone status selected
in 500-03.

506

Verified Account
Codes

506

,

Hold

This program adds or deletes entries in the DR Table associated with
the DRL.

506-00

Account Code

n,

Hold

n =

Up to 15 digits

Enter a valid accounting code that the user will be expected to dial.
Digits 0~9 can be used.

Note

The Account Code is set to the same digit length as the
Verified Digit Length in Program 570 above.