800 Series Programs

Table 1-39

Programs 801~803

Button

Sequence

Value(s)

Summary

801

Network Jack LAN
Device Assignments

801

,

Hold

This screen assigns the LAN parameters for the PC applications
connected to the BECU Network Jack through a LAN or Hub.

801-00

LAN Port Number

n,

Hold

n =

1~12 (default = no value)

Enter the port number of the LAN device to be assigned. Refer to
Program 803 SMDR SMDI CTI Port Assignments.

Notes

•

Program the local port number for LCD Control of Voice Mail

•

Use the same Device Port No. (11) for Network BLF.

•

Use 10 for Network CTX Proprietary Integration

•

Use 12 for Network DSS

Network BLF and DSS are available only with CTX Release 1.3 or
higher software and with CTX WinAdmin Release 1.3 or higher
software.

801-01 Protocol

FB01

, n,

Hold

n =

1.

TCP

(default)

2.

UDP

Select communication Protocol.

Note

Select UDP for Network DSS.

801-02 PC

Operation

Type

FB02

, n,

Hold

n =

1.

Server

(default)

2.

Client

Enter the application PC type: Server or Client.

801-03 Data

Flow

FB03

, n,

Hold

n =

1.

Synchronization

2.

Asynchronization

(default)

Enter the data flow protocol that should take place between the CTX
and PC. If the PC is a CTX, CTI application assign ìAsynchronizationî
to data flow.

801-04

Server Port Number

FB04

, n,

Hold

n =

0~65535

(default = 0)

Enter the Server Port Number and proceed to

07 Read Retry

Number

. This field is required if Server was selected in

02 PC

Operation Type

above. If not, leave this field blank and proceed to

05

Client IP Address

.

Note

Use 6000 for Network BLF, 3000 for Network DSS, and 5000
for Network CTX Proprietary Integration.

801-05 Client

IP

Address

FB05, FB06, FB07,
or FB08

, n,

Hold

n =

0~255

(default = 0)

Enter the Client LAN IP Address. This field is required if Client was
selected in

02 PC Operation Type

above.

0~255 for each octet (default = 0)

Enter IP address of Stratagy iES32 or SES.

801-06

801-07

801-08

801-09

Write Retry Number

FB09

, n,

Hold

n =

0~65535

(default = 0)

Enter the Client Port number. This field is required if Client was
selected in

02 PC Operation Type

above.

801-10

Write Retry Number

FB10

, n,

Hold

n =

0~10

(default = 1)

Set the Read Retry counter to (1~10).

801-11

Write Retry Number

FB11

, n,

Hold

,

Hold

n =

0~10

(default = 1)

Set the Write Retry counter to (1~10).

803

IO Logical Device
Assignment

803

,

Hold

This screen is used to assign:

1. SMDR and SMDI to logical device and BSIS, RS-232 port
numbers.

2. CTX WinAdmin, ACD sever, and Attendant Console to BECU,
Network Jack logical device and LAN port numbers.

803-00 Logical

Device

Number

n,

Hold

n =

100 = SMDR
300 or 301 = SMDI
200~208 = CTI LAN
Devices of PCs (default =
no value)
400 = BLF
500 = DSS

Enter the 3-digit logical device number for SMDR, SMDI, and LAN
device or PC application. See

ìDevice Tableî

on

page 1-95

SMDR: 100

SMDI: 300 or 301

CTI LAN devices or PCs can be assigned to any of the 9 LAN devices
numbers available: 200~208.