Telephone Button Programming

100 Series Programs

1-20

Strata CIX/CTX Telephone Button Programming 11/04

105-18

Night Bell Relay

FB18

, n,

Hold

,

Hold

n =

0~8

(default = 0)

Assign BIOU Relay (1~8) as the Night Relay - this relay activates
when the

system is in the Night Mode.

BIOU1 provides relays 1 to 4.

BIOU2 provides relays 5 to 8

Note

The CTX100 ACTU built-in relay is programmed as relay 5.
For this relay operation, a virtual BIOU2 is installed, as
default, in a virtual equipment position - Cabinet 2 slot 5.
(Cab. 02 slot 05, PCB code 20, in program 100). To install an
actual BIOU2 and disable the ACTU built-in relay, use the
programming telephone. To remove the virtual BIOU2 and
then install the actual BIOU2 in Cab. 01/slot 01~08 in the
normal manner.

105-19

Display Preference

FB19

, n,

Hold

,

Hold

n =

1.

DNIS (default)

2.

Caller ID

Whether to display DNIS or Caller ID.

105-20

Transit Counter

FB20

, n,

Hold

,

Hold

n =

0~128

(default = 1)

The Networking Transit Counter limits the number of nodes through
which a QSIG call can pass before being terminated as a lost call.

105-21

Primary Clock

FB21

, xxyyzz,

Hold

,

Hold

xx =

Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)

Enter data as xxyyzz.

zz=channel 01 if clock source is RPTU or RDTU

zz=channel 01, 02, 03 , or 04 if clock source is RBUU/RBUS or RBSU

Example: If the Primary Clock Source should be a assigned to an
RPTU in cabinet 5, slot 2, enter 050201.

Cabinet numbers:

CTX100: Select 01 for Base and Expansion cabinet.

CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.

Slot numbers:

CTX100: Select 01~04 for Base slots and 05~08 for Expansion
slots.

CTX670: Select 01~08 for Base slots and 01~10 for Expansion
slots.

yy =

Slot 01~8 (CTX100),
01~10 (CTX670)

zz =

Circuit (01~30)

105-22

Secondary Clock

FB22

, xxyyzz,

Hold

,

Hold

xx =

Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)

Enter data as xxyyzz:

zz=channel 01 if clock source is RPTU or RDTU

zz=circuit 01, 02, 03 , or 04 if clock source is RBUU/RBUS or RBSU

Example: If the Secondary Clock Source should be a assigned to an
RBUU in cabinet 5, slot 2, circuit 2; enter 050202.

Cabinet numbers:

CTX100: Select 01 for Base and Expansion cabinet.

CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.

Slot numbers:

CTX100: Select 01~04 for Base slots and 05~08 for Expansion
slots.

CTX670: Select 01~08 for Base slots and 01~10 for Expansion
slots.

yy =

Slot 01~8 (CTX100),
01~10 (CTX670)

zz =

Circuit (01~30)

105-23

Call History Prefix 1

FB23

, n,

Hold

,

Hold

n =

1.

add (default)

2.

not add

Whether prefix 1 is added or not in callback of Call History Feature.

105-24

Emergency Digits
Sent

FB24

, n,

Hold

,

Hold

n =

Up to 5 digits

(default = 911)

Default = м911о for North America. Enter alternative emergency
dialing strings up to 5 digits as required by local conditions.

105-25

DP Make Ratio

FB25

, n,

Hold

,

Hold

n =

1.

DPMakeRatio33

2.

DPMakeRatio40
(default)

Dial pulse Make/Break ratio can be set to 33% or 40%. The default
value is 40%.

Table 1-5

Programs 103~107

(continued)

Button

Sequence

Value(s)

Summary