background image

Telephone Button Programming

200 Series Programs

1-28

Strata CIX/CTX Telephone Button Programming 11/04

200 Series Programs

Table 1-14

Programs 200~202

Button

Sequence

Value(s)

Summary

200

Station Data

200

,

Hold

This command assigns stations to the system.

200-00

Primary DN

n,

Hold

n =

Up to 5 digits

Primary DN (enter an existing PDN or enter a PDN you wish to create
for a new station).

200-01

PDN Equipment
Number

FB01

, xxyyzz,

Hold

xx =

Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)

Enter the PDN equipment number (xxyyzz). This is the cabinet, slot,
and circuit number of the ADKU, BDKU/BDKS, PDKU, or RSTU
interface PCB to which the the PDN is, or should be assigned.

Example: If the PDN should be a assigned to a BDKU in cabinet 5,
slot 2, circuit 3; enter 050203.

Cabinet numbers:

CTX100: Select 01 for Base and Expansion cabinet.

CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.

Slot numbers:

CTX100: Select 01~04 for Base slots and 05~08 for Expansion
slots.

CTX670: Select 01~08 for Base slots and 01~10 for Expansion
slots.

yy =

Slot (01~10)

zz =

Circuit (01~16)

200-02

Station Type

FB02

, n,

Hold

n =

1.

DKT

2.

SLT

Station Type.

Note

Select SLT to set up voice mail.

200-03

Circuit Type

FB03

, n,

Hold

n =

1.

Extension

2.

Voice Mail

3.

Announce (Not used in
USA or Canada)

Extension: Should be assigned to PDNs the are associated with
Digital or Standard telephones

Voice Mail: Should be assigned to PDNs associated with Voice Mail
RSTU circuits.

200-04

Station COS

Day1 COS

Day2 COS

Night COS

FB04

, n,

Spkr

, n,

Spkr

, n,

Hold

n =

1~32

COS for Day1.

COS for Day2.

COS for Night.

200-05

Station DRL

Day1 DRL

Day2 DRL

Night DRL

FB05

, n,

Spkr

, n,

Spkr

, n,

Hold

n =

1~16

DRL for Day1 (Used for Credit card calling).

DRL for Day2.

DRL for Night.

200-06

Station FRL

Day1 FRL

Day2 FRL

Night FRL

FB06

, n,

Spkr

, n,

Spkr

, n,

Hold

n =

1~16

FRL for Day1.

FRL for Day2.

FRL for Night.

200-07

LCR Group

FB07

, n,

Hold

n =

1~16

Station LCR Group Number.

Advertising