Telephone Button Programming

100 Series Programs

Strata CIX/CTX Telephone Button Programming 11/04

1-17

T

e

le

phon

e Butt

on

Pr
og
ramm

ing

103-36

Allow Hook Flash

FB36

, n1,

Hold

Hold

n1 =

1.

Enable (default)

2.

Disable

The privilege to receive hook flash over CO Lines and to allow
telephones to hook flash.

103-37

Automatic Line Hold

FB37

, n1,

Hold

Hold

n1 =

1.

Enable

2.

Disable (default)

The privilege to have an active call automatically held when
accessing another line.

103-38

Can Originate OCA

FB38

, n1,

Hold

Hold

n1 =

1.

Enable

2.

Disable (default)

Permission for others to call this station using Off-hook Call
Announce.

104

System Timers

104

,

Hold

System timers set a variety of times to control calls and features for
the system.

104-01

ACB Callback Timer

FB01

, n,

Hold

Hold

n =

5~180 sec.

(default = 30)

The Automatic Callback timer sets the time (5 ~ 180 seconds) that the
callback will be attempted before being cancelled.

104-02

ACB Cancel Recall
Timer

FB02

, n,

Hold

Hold

n =

5~180 sec.

(default = 30)

The Automatic Callback overall timer sets the time (5 ~ 180 minutes)
that a callback can be registered. Once the timer expires, the callback
will be cancelled.

104-03

Park Recall Timer

FB03

, n,

Hold

Hold

n =

10~600 sec.

(default = 120)

The Park timer sets the length of time (10 ~ 600 seconds) a call can
remain in Park prior to a recall to the station that initiated the Park.

104-04

Camp-on Timer

FB04

, n,

Hold

Hold

n =

5~15 sec.

(default = 10)

The Camp-on timer sets the time (5 ~ 60 seconds) needed to remain
off-hook prior to Camp-on being automatically activated.

104-05

SMDR Valid Call
Timer

FB05

, n,

Hold

Hold

n =

0~180 sec.

(default = 1)

The SMDR Answer timer sets a default time (0 ~ 180 seconds) for
when an outgoing call will be considered to be answered for SMDR
reporting when a true answer signal is not returned from the public
network. Setting the time short will include calls that may not be
completed, setting the time too long may exclude short calls that are
answered and terminated in a short time.

104-06

Tandem Connection
#1

FB06

, n,

Hold

Hold

n =

0~3600 sec.

(default = 300)

For Trunk-to-trunk connections which neither CO Line has release
supervision, a timer (0 ~ 3600 seconds) is needed to release the call
if no user monitoring has taken place.

Also used for CO line to RSTU port connections in which the CO line
has no supervision and the

device connected to the RSTU port does not hang up automatically
(see Prg200, PB34).

104-07

Tandem Connection
#2

FB07

, n,

Hold

Hold

n =

0~180 sec.

(default = 30)

The Trunk-to trunk User Input Timer provides a time (0 ~ 180
seconds) to allow an external user to dial a digit to extend the
disconnect time when the connection is unsupervised. This feature
is used primarily with DISA service.

104-08

Call Forward No Ans
Time

FB08

, n,

Hold

Hold

n =

1~180 sec.

(default = 20)

The System Call Forward No Answer timer (1 ~ 180 seconds)
specifies the time period that a phone will ring prior to invoking the
Call Forward operation.

104-09

Dial Input Timer

FB09

, n,

Hold

Hold

n =

0~60 sec.

(default = 20)

Time system will wait for the beginning of DTMF input.

104-10

Delay 1 Ringing Timer

FB10

, n,

Hold

Hold

n =

1~60 sec.

(default = 12)

The Delayed Ringing 1 timer specifies the time (1 ~ 60 seconds) to
wait before applying ringing to the designated phones.

104-11

Delay 2 Ringing Timer

FB11

, n,

Hold

Hold

n =

1~60 sec.

(default =240)

The Delayed Ringing 2 timer specifies the time (1 ~ 60 seconds) to
wait before applying ringing to the designated phones.

104-12

Door Unlock Timer

FB12

, n,

Hold

Hold

n =

1~30 sec.

(default = 6)

The Door Unlock Timer specifies the length of time (1 ~ 30 seconds)
the electrical signal is sent to the door for releasing the lock.

104-13

9+11 Judgement
Timer

FB13

, n,

Hold

Hold

n =

1~30 sec.

(default = 5)

The 9+11 Inter-digital timer provides a timing value (1 ~ 30 seconds)
for the system to wait for additional digits to be dialed looking for the
911 or 9+911 dialed codes for treatment using the E911 procedures
rather than normal dialing treatment.