1/4 clock output ălevelătests – Tektronix AWG610 User Manual

Page 414

Advertising
background image

Appendix B: Performance Verification

B-54

AWG610 Arbitrary Waveform Generator User Manual

1/4 Clock Output ĂLevelĂTests

These procedures check the AWG610 Arbitrary Waveform Generator clock
output signal.

Equipment

required

A 50ĂW BNC coaxial cable and an oscilloscope.

Prerequisites

The AWG610 Arbitrary Waveform Generator must meet the

prerequisites listed on page B-8.

Do the following steps to install the test hookup and set the test equipment
controls:

1. Use the 50

W

BNC coaxial cable to connect the AWG610 Arbitrary

Waveform Generator 1/4 CLOCK OUT output to the oscilloscope input
connector (see Figure B–29).

AWG610 Arbitrary Waveform

Generator rear panel

OscilloscopeĂ(TDS700)

50 W BNCĂcoaxial cable

1/4ĂCLOCKĂOUT

Figure B-29: 1/4 Clock output level initial test hookup

2. Set the oscilloscope controls as follows:

Vertical . . . . . . . . . . . . . . . . . . . . . . . . . CH1

CH1 coupling . . . . . . . . . . . . . . . . DC
CH1 sca le . . . . . . . . . . . . . . . . . . 0.5 V/div
CH1 offset . . . . . . . . . . . . . . . . . . Ć1.3 V
CH1 input impedance . . . . . . . . . . 1 MW

Horizontal

Sweep . . . . . . . . . . . . . . . . . . . . . 5 ns/div

Trigger

Source . . . . . . . . . . . . . . . . . . . . . CH1
Coupling . . . . . . . . . . . . . . . . . . . . AC
Slope . . . . . . . . . . . . . . . . . . . . . . Positive
Level . . . . . . . . . . . . . . . . . . . . . . 0 V
Mode . . . . . . . . . . . . . . . . . . . . . . Auto

Advertising