Introduction

1–6

975-0307-01-01

Bottom Panel

Network Port

Each network port can accept an eight-pin RJ45 plug attached to a
Category 5 (CAT 5) network cable. Depending on the installation, both
ports may be required.

20-contact
Connector

The 20-contact connector supports a wiring harness (included) that
connects the XW Auto Generator Start to a generator and thermostats.
The wiring harness also provides lines for connecting external generator
shutdown sensors or switches and external generator ON/OFF controls.

Figure 1-3 XW Auto Generator Start Bottom Panel

CAUTION:
Connect only to Class
2 ELV circuits.
Refer to manual.

!

Network

Generator

20-contact Generator
Connector Port

Network Port
(accepts eight-pin
RJ45 plug)

CAUTION: Equipment Damage

Connect the XW Auto Generator Start only to other Xanbus compatible devices.

Although the cabling and connectors used in this network system are the same as
those used for Ethernet, this network is not an Ethernet system. Equipment
damage may result from attempting to connect these two different systems.

Figure 1-4 Wiring Harness