12.7.2 Syntax
Command syntax : +STGR=<CmdType>[,<Result>,<Data>]
Command
Possible responses
+STGR=<CmdType>[,<Result>,<Data>]
OK
+CME ERROR: <err>
For GetInput with <Result>=1:
+STGR=3,1<CR>
<Data><Ctrl Z>
OK
+CME ERROR: <err>
For GetInkey with <Result>=1
+STGR=2,1,.<Data>.
OK
+CME ERROR: <err>
+STGR=? OK
12.7.2.1 Defined
values
<CmdType>
0:
Item selection in the main menu.
1: User confirmation to clear a ‘Disp Text’.
2: Response for a ‘Get Inkey’.
3: Response for a ‘Get Input’.
4: Response for a ‘Setup call’.
6: Response for a ‘Sel Item’.
11 Response for a ‘Setup event list’.
95 Backward move
96 Command beyond ME capabilities
97 ME currently unable to process command
98 No response from the user.
99 User abort.
Values when CmdType=0 (Select an item from the main menu)
<Result>
1:
Item selected by the user.
2:
Help information required by user.
<Data> Contains the item identifier of the item selected by the user.
Values when CmdType=1 (Confirm the display text clearing)
No values.
Values when CmdType=2 (Get Inkey)
<Result>