10.5.2 Syntax:
Command syntax : AT+CLIR=<n>
Response syntax : +CLIR :<n>,<m> (for AT+CLIR ?)
Command
Possible responses
AT+CLIR=1 OK
AT+CLIR?
+CLIR: 1,0
OK
AT+CLIR =2
OK
AT+CLIR =0
OK
10.5.3 Defined
values:
<n>: sets the line ID restriction for outgoing calls
0: Presentation indicator is used according to the subscription of the CLIR service
1: CLIR invocation
2: CLIR suppression
<m>: shows the subscriber CLIR status in the network
0: CLIR not provisioned
1: CLIR provisioned in permanent mode
2: Unknown (no network…)
3: CLIR temporary mode presentation restricted
4: CLIR temporary mode presentation allowed
10.6 Calling line identification presentation +CLIP
10.6.1 Description:
This command allows control of the Calling Line Identifier presentation supplementary service. When
presentation of the CLI (Calling Line Identifier) is enabled (and calling subscriber allows), +CLIP
response is returned after every RING result code.
10.6.2 Syntax
:
Command syntax: AT+CLIP=<n>
Response syntax:
+CLIP: <n>,<m> (as response to AT+CLIP?)
+CLIP: <number>, <type>[ ,<subaddr>, <satype>, <alpha> ] (for an incoming call, after each
RING indication)
Command
Possible responses
AT+CLIP=0
Note: deactivate CLIP
OK