19 flyfot status request +wstr, 1 description, 2 syntax – Rainbow Electronics 900 User Manual

Page 187: 3 defined values, 19 flyfot, Status request +wstr

Advertising
background image

FLYFOT-M260-MODULE

Page: 187 / 239

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.

0 : Controller 1 (Default)
1 : Controller 2

18.19 FLYFOT Status Request +WSTR

18.19.1 Description :

This specific command returns some operation status. It can be used for example to check the state of
the initialisation sequence; the different values returned are Not started, Ongoing, Finished.

18.19.2 Syntax :

Command syntax: AT+WSTR=<status>
Response syntax: +WSTR: <status>,<value>

Command

Possible responses

AT+WSTR=<status>

+WSTR :<status>,<value>

AT+WSTR=1

+WSTR: 1,2

Note : Select the status 1 (INIT SEQUENCE)

OK

Note : Init finished

AT+WSTR=2

+WSTR: 2,1

Note : Select the status 2 (NETWORK

OK

STATUS)

Note : The network is available

AT+WSTR=?

+WSTR: (1-2)

Note : Ask for the list of possible values

Note : possible values : 1 and 2

18.19.3 Defined values

<status>

1 : Initialisation sequence

<value>
0 : Not started
1 : On going
2 : Finished


2 : Network status

<value>

0 : No network
1 : Network available

Advertising