4 general commands, 1 module initial reason +tinit, 1 description – Rainbow Electronics 900 User Manual
Page 13: 2 syntax, 3 defined values, 2 battery state +cbc, 4 general, Commands, 1 module, Initial reason +tinit

FLYFOT-M260-MODULE
Page: 13 / 239
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged
without prior written agreement.
4 General commands
4.1 Module initial reason +TINIT
4.1.1 Description
:
Request module initial reason.
4.1.2 Syntax:
Command syntax : AT+TINIT
Command
Possible responses
AT+TINIT=? OK
AT+TINIT?
+TINIT: 0,n
Note: onkey init
+TINIT: 1,n "YY/MM/DD,hh:mm:00"
Note: wakup init
"YY/MM/DD,hh:mm:00" is the time of alarm
clock
+TINIT: 2,n
Note: watchdog init
+TINIT: 3,n
Note: plugin init
+TINIT: 4,n
Note: restart init
+TINIT: 5,n
Note: error init
OK
AT+TINIT
AT+TINIT=1
+CME ERROR 3
Note: not support
4.1.3 Defined
values
:
<n>
0: airplane mode is off
1: airplane mode is on
4.2 Battery state +CBC
4.2.1 Description
:
Request module battery state.
4.2.2 Syntax
:
Command syntax : AT+CBC