17.10 AT+CIPHEAD

AT+CIPHEAD Set whether add a header to data received

Test command

AT+

CIPHEAD

=?

Response

+CIPHEAD:(0-NO HEADER,1-ADD HEADER)

OK

AT+CIPHEAD?

Response

<mode>
OK

Parameter

See set command

AT+ CIPHEAD =<
mode >

Response

This command is used to add a header to data received from TCP/UDP
connection,distinguishing data received by other way such as SMS
OK,
ERROR

Parameter

<mode>
0 no header
1 set header,

Reference

Note

The header format is “+IPD(data length):”

17.11 AT+CIPATS

AT+ CIPATS Set auto send timer

Test command

AT+

CIPATS

=?

Response

+CIPATS:(0-NOT AUTO SEND,1-AUTO SEND)

OK

AT+ CIPATS =
<mode>,<time>

Parameter

<mode>
0 not set timer of sending data