6.4.2 Syntax
:
Command syntax : AT+CPOL=
[<index>] [,<format>[,<oper>[,<GSM_AcT>,<GSMcomp_Act>,<Utran_Act>]]]
The different possibilities are:
z
AT+CPOL = <index> to delete an entry.
z
AT+CPOL = , <format> to set the format used by the read command (AT+CPOL?).
z
AT+CPOL = <index> , <format> , <oper> to write <oper> in the
<format> at the <index>.
The supported format are those of the +COPS command.
Command
Possible responses
AT+CPOL?
Note : Ask for preferred list of networks
With only EF_PLMNsel present
+CPOL: 1,2,46000
OK
Note : Preferred list of networks in numeric format
(read in EF_PLMNsel)
AT+CPOL=,0
Note : Select long alphanumeric format
OK
AT+CPOL?
Note : Ask for preferred list of networks With only
EF_PLMNsel present
+CPOL: 1,0,"CHINA TELECOM"
OK
Note : Preferred list of networks in long
alphanumeric format
AT +CPOL=7 , 2 , 46001
Note : Add a network to the list
OK
Note: succeed
AT+CPOL = 7
Note : Delete 7
th
location
OK
Note: succeed
AT+CPOL = ?
Note: get the max index
+CPOL:(0~8),(0~2)
OK
Note: succeed
6.4.3 Defined
values
:
<index> : position of the operator record in the sim preferred operator list. Do
AT+CPOL=? To get the maximum index of the selected EF.
<format> :
0 long alphanumeric format for <oper>
1 short alphanumeric format for <oper>
2 numeric format for <oper>
<oper> : character string or integer (see <format>) indicating operator identifier.