1 description, 2 syntax, 3 defined values – Rainbow Electronics 900 User Manual
Page 204: 34 features management +wfm, 34 features, Management

FLYFOT-M260-MODULE
Page: 204 / 239
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.
Note :
When the <BattIntRes> parameter is changed, the product must be reset to
take the modification into account.
18.33 Unsolicited result : FLYFOT Battery Charge Indication +WBCI
18.33.1 Description
This unsolicited indication returns information about the battery charge (maximum level
reached, current battery voltage).
18.33.2 Syntax
Unsolicited response syntax : +WBCI: <Status>[,<BattLevel>]
18.33.3 Defined values
<Status>
0 : Minimum battery level reached. The battery is considered as discharged.
The product is turned off (as with the +CPOF command).
1 : Maximum battery level reached. The battery is considered as charged.
The battery charging is stopped.
2 : Battery currently in charge.
3 : Battery currently out of charge.
<BattLevel> : Current battery voltage during or out of the charging.
The possible range is [2800 ; 5000]. (in mV)
Note :
<Status> = 2 and 3 are solicited, by the AT+WBCM=2 command, or unsolicited when the <ChargeInd>
parameter of the +WBCM command is set to 1. With these <Status> values, the <BattLevel> parameter is
also present.
18.34 Features Management +WFM
18.34.1 Description
This specific command allows some features to be enabled or disabled.
Note :
After a modification, the changes will be taken into account only after a reset of the product.
18.34.2 Syntax
Command syntax AT+WFM=<mode>[,<FtrID>]