IAI America E-Con User Manual

Page 101

Advertising
background image

93

5. T

abletop Robot TT

(3)

When the number of I/O points is set to 208 or more and 256 or less:

Configured as three remote devices. (Three stations occupied)

I/O parameter

No. 14 No. 15

TT side DI

(Port No.)

PLC side

TT side DO

(Port No.)

PLC side

(16) (16)

048-063

RY

0 – F

348 - 363

RX

0 – F

(32) (32)

064-079

RY 10

1F 364 - 379

RX 10

1F

(48) (48)

080-095

RY

20

2F

380 - 395

RX

20

2F

(64) (64)

096-111

RY

30

3F

396 - 411

RX

30

3F

(80) (80)

112-127

RY

40

4F

412 - 427

RX

40

4F

(96) (96)

128-143

RY

50 – 5F

428 - 443

RX

50 – 5F

(112) (112)

144-159

RWw 0

444 - 459

RWr 0

(128) (128)

160-175

RWw 1

460 - 475

RWr 1

(144) (144)

176-191

RWw 2

476 - 491

RWr 2

(160) (160)

192-207

RWw 3

492 - 507

RWr 3

(176) (176)

208-223

RWw 4

508 - 523

RWr 4

(192) (192)

224-239

RWw 5

524 - 539

RWr 5

208 208

240-255

RWw 6

540 - 555

RWr 6

224 224

256-271

RWw 7

556 - 571

RWr 7

240 240

272-287

RWw 8

572 - 587

RWr 8

Not be set

-

RWw 9

-

RWr 9

Not be set

-

RWw A

-

RWr A

Not be set

-

RWw B

-

RWr B

* Since the shaded portions are the system areas for the remote device station on the PLC side, they

cannot be used as I/O.

* In the case of three stations being occupied, twelve words (nine words for TT) are assigned for each

input and output in the data register on the PLC side. Be careful about overlapping of data register on

the PLC side.