3. X-SEL-J/K/P/Q/JX/KX/PX/QX

3.1.3 Setting of I/O parameters (assignment of I/O ports)

The X-SEL I/O ports used in the CC-LINK are set. X-SEL allows a variety of settings of different I/O ports with I/O

parameters. (For further information, refer to the X-SEL Controller Operation Manual.)

The typical setting methods are shown below in this Manual.

Basically, the I/O parameter No. 1 sets the I/O port assignment type to fixed assignment, and sets the I/O port

address for each I/O slot.

(1)

Board installation positions (slots) and parameter numbers

a. J

type

(Three- and four-axes
specifications)

Parameter No. 4
No.

5

No.

11

Parameter No. 2
No.

3

No.

10

Parameter No. 8
No.

9

No.

13

Parameter No. 6
No.

7

No.

12

Parameter No. 4
No.

5

No.

11

Parameter No. 2
No.

3

No.

10

Note: With no slots, parameters No. 6 to No. 9 are all set to “-1” and parameters No. 12 and No. 13 are set to “0.”

For the single-axis and two-axes specifications, parameters No. 4 and No. 5 are set to “-1” and parameter No.

11 is set to “0.”