IAI America E-Con User Manual

Page 136

Advertising
background image

128

8.

ASEL, PSEL, SSEL

(4)

In the case of using it in the SSEL Positioner Mode:

Regardless of the settings for the I/O parameter No. 1, No. 16 and No. 17, the Nos. starting from “0” are

allocated to the physical input ports and Nos. starting from “300” to the physical output ports.

Then, the Input Port No. 0 to No. 23 and Output Port No. 300 to No. 30 are used as in the I/O Port Table for

Each Controller described from the next page.

At that time, make sure to set the values for the I/O parameter No. 14 and No. 15 to “104” or larger.

* When the values for the I/O parameter No. 14 and No. 15 are set to “96” or smaller, because the Input

Port No. 16 to No. 31 and Output Port No. 316 to No. 331 are within the remote device station system

domain as shown in Item (1), the positioner mode is not available.

* When the values for the I/O parameter No. 14 and No. 15 are set to “104” or larger, because the Input

Port No. 16 to No. 23 are not within the remote device station system domain as shown in Items (2) and

(3), the positioner mode is available.

* When the values for the I/O parameter No. 14 and No. 15 are set to “96” or smaller, because the Input

Port No. 16 to No. 31 and Output Port No. 316 to No. 331 are within the remote device station system

area as shown in Item (1), the positioner mode is not available.

* When the values for the I/O parameter No. 14 and No. 15 are set to “104” or larger, because the Input

Port No. 16 to No. 23 are not within the remote device station system area as shown in Items (2) and

(3), the positioner mode is available.