4. XSEL-R/S/RX/SX/RXD/SXD

[7] I/O Port Top Number Setting

Set the top port number of the port range used in I/O Parameters No. 233 to 234.

Note

The port numbers assigned here are the starting input and output port numbers. Add the
number of ports assigned in parameters 231 and 232 to determine the I/O range.
The values entered into these parameters must be evenly divisible by 8 (EX: 300).

No.

Parameter name

Default

(Reference)

Input Range

Unit

Remarks

233

Network I/F Module 2
Input Port Start No. in
Network I/F

-1

-1 to 299

1000t to

3999

-

0+(Multiples of 8)
or
1000+(Multiples of 8)
[Ineffective when -1 is selected]

234

Network I/F Module 2
Input Port Start No. in
Network I/F

-1

-1

300 to 599

4000 to

6999

-

300+(Multiples of 8)
or
4000+(Multiples of 8)
[Ineffective when -1 is selected]

[8] Time Setting to Wait for CC-Link Communication Establishment

To I/O Parameter No. 120, set the maximum allowable time to establish CC-Link
communication at the start.

Change this setting when XSEL starts faster than the master unit, which results in a
generation of D5D or A6B.

No.

Parameter name

Default

(Reference)

Input Range

Unit

Remarks

120 Network attribute 1

640001H

0 to

FFFFFFFFH

100ms

Bits 16 to 23:
Value of Link Timeout at initializing
(Example) The initial value

640001His bit 16 to 23
= 64H = 100 (in 100ms
unit)

100×100ms = 10sec
It waits for 10sec at maximum
from the startup for the
communication establishment.

[9] Data Retaining Setting at CC-Link Communication Error

Set in I/O Parameter No. 121 whether to clear the input port data to 0 or to retain it at a
communication error.

No.

Parameter name

Default

(Reference)

Input Range

Unit

Remarks

121 Network attribute 2

0H

0 to

FFFFFFFFH

-

Bits 8 to 15:
Input port data selected at Network
I/F Module 2 link error

0: Input port data clear
1: Input port data retained

0+ (Multiples of 8)
or
1000+ (Multiples of 8)
[Ineffective when -1 is selected]
300+ (Multiples of 8)
or
4000+ (Multiples of 8)
[Ineffective when -1 is selected]

Bits 16 to 23:
Value of Link Timeout at initializing
(Example) The initial value

640001H is bit 16 to 23
= 64H = 100 (in 100ms
unit)

100×100ms = 10sec
It waits for 10sec at maximum
from the startup for the
communication establishment.

Extension Input Port Start
No. at Network I/F Module 2
Fixed Assignment

Extension Output Port Start
No. at Network I/F Module 2
Fixed Assignment