Tt type i/o parameters – IAI America E-Con User Manual

Page 97

Advertising
background image

89

5. T

abletop Robot TT

TT type I/O parameters

No. Parameter

name

Default

(reference)

Input

range

Setting Remarks

1

I/O port assignment type

0

Reference

only

0

0: Fixed assignment

2

Standard I/O fixed assignment time:

Input port start No.

000 Reference

only

000

0+(multiples of 8)(Invalid for negative

values)

3

Standard I/O 1 fixed assignment time:

Output port start No.

300 Reference

only

300

300+(multiples of 8)(Invalid for negative

values)

4

Standard I/O 2 fixed assignment time:

Input port start No.

32 Reference

only

32

0+(multiples of 8)(Invalid for negative

values)

5

Standard I/O 2 fixed assignment time:

Output port start No.

316

-1

316

300+(multiples of 8)(Invalid for negative

values)

6

Expansion I/O 1 fixed assignment time:

Input port start No.

(Network I/F module)

48

-1-599

48

0+(multiples of 8) (Invalid for negative

values)

7

Expansion I/O 1 fixed assignment time:

Output port start No.

(Network I/F module)

348

-1

348

300+(multiples of 8)(Invalid for negative

values)

8

System reservation

-1

-1 - 599

-1

9

System reservation

-1

-1 - 599

-1

10

Standard I/O 1 error monitoring

0

0 – 5

0

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V

I/O power related errors)

3: Monitoring (Monitoring of 24V I/O

power related errors only)

* Some exceptions included.

11 Expansion I/O 2 error monitoring

0

0 - 5

0

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V

I/O power related errors)

3: Monitoring (Monitoring of 24V I/O

power related errors only)

* Some exceptions included.

12

Expansion I/O 1 error monitoring

(Network I/F module)

1

0 - 5

1

0: Non-monitoring

1: Monitoring

* Some exceptions included.

13

System reservation

1

0 - 5

1

14

Network I/F card remote: Number of

ports used for input

64

0 - 240

240

Multiples of 16

15

Network I/F card remote: Number of

ports used for output

64

0 - 240

240

Multiples of 16

Advertising