IAI America E-Con User Manual

Page 85

Advertising
background image

77

4. XSEL-R/S/RX/SX/RXD/SXD

(4) Assignment of System Domain Signals

It is only Remote Station Ready that is used in the system domain.
When set to occupy one station n = 1, when set to occupy two stations n = 3, when set to occupy three

stations n = 5

PLC Side

Signal assignment

PLC Side

Signal assignment

RY n0

RX n0

RY n1

RX n1

RY n2

RX n2

RY n3

RX n3

RY n4

RX n4

RY n5

RX n5

RY n6

RX n6

RY n7

RX n7

RY n8

RX n8

RY n9

RX n9

RY nA

Unavailable

RX nA

RY nB

Remote station Ready
It turns on when the startup of XSEL
controller is complete, and informs PLC
(master).

RX nB

RY nC

RX nC

RY nD

RX nD

RY nE

RX nE

RY nF

Unavailable

RX nF

Unavailable

(4) Assignment of System Area Signals

It is only Remote Station Ready that is used in the system area.
When set to occupy one station n = 1, when set to occupy two stations n = 3, when set to occupy three
stations n = 5

RY nB

RX nB

Advertising