19

3. X-SEL-J/K/P/Q/JX/KX/PX/QX

(2)

Factory-configured parameters of J/K type (standard setting)

No. Parameter

name

Input

range

Set

value

Remarks

1

I/O port assignment type

0 – 20

1

0: Fixed assignment

1: Automatic assignment (Priority: slot 1

᫦)

* The ports only in the continuous installation

range from slot 1 are assigned for safety.)

2 Standard

I/O:

Input port start No. (I/O 1)

-1 – 599

000

0 + (multiples of 8) (Invalid for negative values)

3 Standard

I/O:

Output port start No. (I/O 1)

-1 – 599

300

300 + (multiples of 8)

(Invalid for negative values)

4

Expansion I/O 1 fixed assignment

time: Input port start No. (I/O 2)

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

(Slot next to the standard I/O)

5

Expansion I/O 1 fixed assignment

time: Output port start No. (I/O 2)

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

6

Expansion I/O 2 fixed assignment

time: Input port start No. (I/O 3)

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

7

Expansion I/O 2 fixed assignment

time: Output port start No. (I/O 3)

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

8

Expansion I/O 3 fixed assignment

time: Input port start No. (I/O 4)

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

9

Expansion I/O 3 fixed assignment

time: Output port start No. (I/O 4)

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

10 Standard I/O error monitoring (I/O 1)

0 – 5

2

11 Expansion I/O 1 error monitoring (I/O

2)

0 – 5

0

12 Expansion I/O 2 error monitoring (I/O

3)

0 – 5

0

13 Expansion I/O 3 error monitoring (I/O

4)

0 – 5

0

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O power

related errors)

(Main application of Ver. 0.55 or later)

3: Monitoring (Monitoring of 24V I/O power related

errors only)

(Main application of Ver. 0.55 or later)

14 Network I/F card remote:

Number of ports used for input

0 – 256

64

Multiples of 16

15 Network I/F card remote:

Number of ports used for output

0 – 256

64

Multiples of 16

(I/O 1) to (I/O 4) indicate the slot numbers.