3. X-SEL-J/K/P/Q/JX/KX/PX/QX

3.1.7 Correspondence between X-SEL I/O port number and PLC address

PLC sets the X-SEL CC-Link board as a remote device.

The number of occupied stations of the remote device varies according to the setting of the number of I/O

points on the X-SEL side.

The table below indicates the correspondence between the I/O port number and PLC address according to

the settings of I/O parameters No. 14 and No. 15. (The following is a case where the I/O parameters No. 2

and No. 3 have standard settings [defaults].)

Note: For the I/O parameters No. 14 and No. 15, set the same points according to the larger number of points.

(1)

When the number of I/O points is set to 96 or less:

Configured as one remote device. (One station occupied)

I/O parameter

No. 14 No. 15

X-SEL side DI

(Port No.)

PLC side

X-SEL side DO

(Port No.)

PLC side

16

16

000 – 015

RY

0 – F

300 – 315

RX

0 – F

32 32

016 – 031

RY

10 – 1F

316 – 331

RX

10 – 1F

48

48

032 – 047

RWw 0

332 – 347

RWr 0

64

64

048 – 063

RWw 1

348 – 363

RWr 1

80

80

064 – 079

RWw 2

364 – 379

RWr 2

96

96

080 – 095

RWw 3

380 – 395

RWr 3

* Since the shaded portions are the system areas for the remote device station on the PLC side, they

cannot be used as I/O.

(2)

When the number of I/O points is set to 112 or more and 192 or less:

Configured as two remote devices. (Two stations occupied)

I/O parameter

No. 14 No. 15

X-SEL side DI

(Port No.)

PLC side

X-SEL side DO

(Port No.)

PLC side

(16)

(16)

000 – 015

RY

0 – F

300 – 315

RX

0 – F

(32)

(32)

016 – 031

RY

10 – 1F

316 – 331

RX

10 – 1F

(48)

(48)

032 – 047

RY

20 – 2F

332 – 347

RX

20 – 2F

(64) (64)

048 – 063

RY

30 – 3F

348 – 363

RX

30 – 3F

(80)

(80)

064 – 079

RWw 0

364 – 379

RWr 0

(96)

(96)

080 – 095

RWw 1

380 – 395

RWr 1

112

112

096 – 111

RWw 2

396 – 411

RWr 2

128

128

112 – 127

RWw 3

412 – 427

RWr 3

144

144

128 – 143

RWw 4

428 – 443

RWr 4

160

160

144 – 159

RWw 5

444 – 459

RWr 5

176

176

160 – 175

RWw 6

460 – 475

RWr 6

192

192

176 – 191

RWw 7

476 – 491

RWr 7

* Since the shaded portions are the system areas for the remote device station on the PLC side, they

cannot be used as I/O.

Advertising
This manual is related to the following products: