5. T

abletop Robot TT

(3)

Transmission and receipt of signals in remote register areas

The I/O parameter No. 120 allows the data in one word (16 bits) to be transmitted by reversing the order of

the higher-order byte (higher-order 8 bits) and the lower-order byte (lower-order 8 bits).

(a) When the I/O parameter No. 120 is set to “1”

ṳ: On, ṯ: OFF

TT port No. (Input)

127 126 125 124 123 122 121 120 119

118

117

116 115 114 113 112

ON/OFF

Hexadecimal data

F

0

8

1

PLC: RWwn (Output)

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

ON/OFF

Hexadecimal data

F

0

8

1

TT port No. (Output)

427 426 425 424 423 422 421 420 419 418 417 416 415 414 413 412

ON/OFF

Hexadecimal data

F

0

8

1

PLC: RWrn (Input)

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

ON/OFF

Hexadecimal data

F

0

8

1