No. Parameter

name

Default

(reference)

Input

range

Setting Remarks

1

I/O port assignment type

0

0 – 20

0

0: Fixed assignment

1: Automatic assignment (Priority: slot 1

᫦)

* The ports only in the continuous

installation range from slot 1 are

assigned for safety.)

2

Standard I/O fixed assignment

time:

Input port start No. (I/O 1)

-1

-1 – 599

000

0 + (multiples of 8) (Invalid for negative values)

3

Standard I/O fixed assignment

time:

Output port start No. (I/O 1)

-1

-1 – 599

300

300 + (multiples of 8)

(Invalid for negative values)

4

Expansion I/O 1 fixed assignment

time: Input port start No. (I/O 2)

032

-1 – 599

032

0 + (multiples of 8) (Invalid for negative values)

(Slot next to the standard I/O)

5

Expansion I/O 1 fixed assignment

time: Output port start No. (I/O 2)

332

-1 – 599

316

300 + (multiples of 8)

(Invalid for negative values)

6

Expansion I/O 2 fixed assignment

time: Input port start No. (I/O 3)

016

-1 – 599

048

0 + (multiples of 8) (Invalid for negative values)

7

Expansion I/O 2 fixed assignment

time: Output port start No. (I/O 3)

316

-1 – 599

332

300 + (multiples of 8)

(Invalid for negative values)

8

Expansion I/O 3 fixed assignment

time: Input port start No. (I/O 4)

000

-1 – 599

064

0 + (multiples of 8) (Invalid for negative values)

9

Expansion I/O 3 fixed assignment

time: Output port start No. (I/O 4)

300

-1 – 599

348

300 + (multiples of 8)

(Invalid for negative values)

10 Standard I/O error monitoring (I/O

1)

0

0 – 5

1

11 Expansion I/O 1 error monitoring

(I/O 2)

2

0 – 5

2

12 Expansion I/O 2 error monitoring

(I/O 3)

2

0 – 5

2

13 Expansion I/O 3 error monitoring

(I/O 4)

2

0 – 5

2

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O

power related errors)

(Main application of Ver. 0.55 or later)

3: Monitoring (Monitoring of 24V I/O power

related errors only)

(Main application of Ver. 0.55 or later)

14 Network I/F card remote:

Number of ports used for input

0

0 – 256

0

Multiples of 8

15 Network I/F card remote:

Number of ports used for output

0

0 – 256

0

Multiples of 8

(I/O 1) to (I/O 4) indicate the slot numbers.