3. X-SEL-J/K/P/Q/JX/KX/PX/QX

3.1.8 Data in remote registers

Addresses in PLC are assigned to the remote I/O addresses and remote register areas that correspond to

the station number set on the CC-Link board and the number of occupied stations set by the PLC parameter,

in steps of 16 points (one word) in order of X-SEL port number.

Setting the I/O parameter No. 120 to “0” allows the data in one word to be transmitted by reversing the

order of the higher-order byte (higher-order 8 bits) and the lower-order byte (lower-order 8 bits) in the

communications area with the PLC remote register. (Remote I/O areas are not changed.)

I/O parameters

No. Parameter

name

Default

(reference)

Input range

Remarks

120 Network attribute 1

1

0H – FFFFFFFFH CC-Link remote register area H/L byte

SWAP selection

0: X-SEL side: H byte

l PLC side: L byte

X-SEL side: L byte

l PLC side: H byte

1: X-SEL side: H byte

l PLC side: H byte

X-SEL side: L byte

l PLC side: L byte

(Main application of Ver. 0.55 or later)

The relationships between I/O signals are shown below by taking s case where the number of I/O points of X-SEL

is set to 112 or more and 192 or less (two stations occupied) for example.

(1)

X-SEL remote I/O areas and remote register areas

Remote input: Port No. 0 to No. 63

Remote output: Port No. 300 to No. 363

Remote address (input): Port No. 64 to No. 191

Remote address (output): Port No. 364 to No. 491

Note: Since ports No. 48 to No. 63 and No. 348 to No. 363 are the system areas for the remote device stations on the

PLC side, they cannot be used.