2) factory-configured parameters of tt type – IAI America E-Con User Manual

Page 95

Advertising
background image

87

5. T

abletop Robot TT

(2)

Factory-configured parameters of TT type

No. Parameter

name

Default

(reference)

Input range

Remarks

1

I/O port assignment type

0

Reference

only

0: Fixed assignment

2

Standard I/O fixed assignment time:

Input port start No.

000 Reference

only

0+(multiples of 8)(Invalid for negative values)

3

Standard I/O 1 fixed assignment time:

Output port start No.

300 Reference

only

300+(multiples of 8)(Invalid for negative values)

4

Standard I/O 2 fixed assignment time:

Input port start No.

32 Reference

only

0+(multiples of 8)(Invalid for negative values)

5

Standard I/O 2 fixed assignment time:

Output port start No.

316

-1

300+(multiples of 8)(Invalid for negative values)

6

Expansion I/O 1 fixed assignment time:

Input port start No.

(Network I/F module)

48

-1-599

0+(multiples of 8) (Invalid for negative values)

7

Expansion I/O 1 fixed assignment time:

Output port start No.

(Network I/F module)

348

-1

300+(multiples of 8)(Invalid for negative values)

8

System reservation

-1

-1 - 599

9

System reservation

-1

-1 - 599

10

Standard I/O 1 error monitoring

0

0 – 5

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O power

related errors)

3: Monitoring (Monitoring of 24V I/O power related

errors only)

* Some exceptions included.

11

Expansion I/O 2 error monitoring

0

0 - 5

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O power

related errors)

3: Monitoring (Monitoring of 24V I/O power related

errors only)

* Some exceptions included.

12

Expansion I/O 1 error monitoring

(Network I/F module)

1

0 - 5

0: Non-monitoring

1: Monitoring

* Some exceptions included.

13

System reservation

1

0 - 5

14

Network I/F card remote: Number of

ports used for input

64

0 - 240

Multiples of 16

15

Network I/F card remote: Number of

ports used for output

64

0 - 240

Multiples of 16

In the case of TT, the number of ports used in the CC-Link can be changed by parameter setting.

The I/O port start No. of the CC-Link is fixed.

CC-Link input port start No. 48

CC-Link output port start No. 348

The I/O port No. of the standard I/O (rear panel I/O connector) is fixed.

Standard input port No. 16 to 31.

Standard output port No. 316 to 331.

Advertising