X-sel j/k type controller i/o parameter – IAI America E-Con User Manual

Page 30

Advertising
background image

22

3. X-SEL-J/K/P/Q/JX/KX/PX/QX

X-SEL J/K type controller I/O parameter

No. Parameter

name

Default

(reference)

Input

range

Setting Remarks

1

I/O port assignment type

1

0 – 20

1

0: Fixed assignment

1: Automatic assignment (Priority: slot 1

᫦)

* The ports only in the continuous

installation range from slot 1 are

assigned for safety.)

2 Standard

I/O:

Input port start No. (I/O 1)

000

-1 – 599

000

0 + (multiples of 8) (Invalid for negative values)

3 Standard

I/O:

Output port start No. (I/O 1)

300

-1 – 599

300

300 + (multiples of 8)

(Invalid for negative values)

4

Expansion I/O 1 fixed assignment

time: Input port start No. (I/O 2)

-1

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

(Slot next to the standard I/O)

5

Expansion I/O 1 fixed assignment

time: Output port start No. (I/O 2)

-1

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

6

Expansion I/O 2 fixed assignment

time: Input port start No. (I/O 3)

-1

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

7

Expansion I/O 2 fixed assignment

time: Output port start No. (I/O 3)

-1

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

8

Expansion I/O 3 fixed assignment

time: Input port start No. (I/O 4)

-1

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

9

Expansion I/O 3 fixed assignment

time: Output port start No. (I/O 4)

-1

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

10 Standard I/O error monitoring (I/O

1)

2

0 – 5

2

11 Expansion I/O 1 error monitoring

(I/O 2)

0

0 – 5

0

12 Expansion I/O 2 error monitoring

(I/O 3)

0

0 – 5

0

13 Expansion I/O 3 error monitoring

(I/O 4)

0

0 – 5

0

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O

power related errors)

(Main application of Ver. 0.55 or later)

3: Monitoring (Monitoring of 24V I/O power

related errors only)

(Main application of Ver. 0.55 or later)

14 Network I/F card remote:

Number of ports used for input

64

0 – 256

64

Multiples of 16

15 Network I/F card remote:

Number of ports used for output

64

0 – 256

64

Multiples of 16

(I/O 1) to (I/O 4) indicate the slot numbers.