4. XSEL-R/S/RX/SX/RXD/SXD

(3) Example for when using CC-Link and I/O Board 1 together

It is how to establish the setting when using CC-Link to 192 ports of each input and output from the top

of the extended I/O ports and assigning the I/O board (48 ports for each input and output) to the
standard I/O ports.

Standard Input Ports No.0 to 191

Standard Input Port No.192 to 239

Standard Output Ports No.300 to 491

Standard Output Port No.492 to 539

(CC-Link board)

(I/O board)

Ɣ I/O Parameters

No.

Parameter name

Default

(Reference)

Input

Range

Unit

Remarks

1

I/O

Port

Allocation Type

1

0 to 1

0

0: Fixed Allocation
1: Automatic Allocation

x

Reference 1 Priority of I/O Port

Assignment when automatically
assigned

1) to Port Number

(No.0 to 299/No.300 to 599)

2) No. of Network I/F Module 1
3) I/Oslot 1(I/O1) Mounting board
4) I/Oslot 2(I/O2) Mounting board
* I/Oslot 1(I/O1) Assigned for the

continuously mounted range from
mounting board

x

Reference 1 Priority of I/O Port

Assignment when automatically
assigned

1) to Port Number

(No.1000 to 3999/No.4000 to
6999)

2) No. of Network I/F Module 2
3) Expansion I/O unit
4) IA Net

2

Standard I/O Fix-Allocated
Input Port Start No

0

-1 to 599

192

0+(Multiples of 8)
[Ineffective when -1 is selected]

3

Standard I/O Fix-Allocated
Input Port Start No

300

-1 to 599

492

300+(Multiples of 8)
[Ineffective when -1 is selected]

Port Number
(No.0 to 299/No.300 to 599)

Reference 2

Priority of extension
I/O ports at automatic assignment
Port Number
(No.1000 to 3999/No.4000 to
6999)

Reference 1

Priority of I/O Port Assignment
when automatically assigned
Port Number
(No.0 to 299/No.300 to 599)

It is how to establish the setting when using CC-Link to 192 points of each input and output from the
top of the extended I/O ports and assigning the I/O board (48 points for each input and output) to the
standard I/O ports.

I/O Port Allocation Type

Standard I/O Fix-Allocated
Output Port Start No.

Standard I/O Fix-Allocated
Input Port Start No.

1) Network I/F Module 1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the

continuously mounted range from
mounting board

1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net

0+ (Multiples of 8)
[Ineffective when -1 is selected]
300+ (Multiples of 8)
[Ineffective when -1 is selected]