6. Operation of SEP

Controllers

I/O display on monitor screen

Displayed item

PIO pattern

operation mode

IN3 (input)/OUT3 (output)

IN2 (input)/OUT2 (output)

IN1 (input)/OUT1 (output)

IN0 (input)/OUT0 (output)

Input

-/

SON (servo ON signal) *1

-/

(RES (reset signal))

-/

*STP (pause signal)

ST0 (move signal)

Standard

movement
between 2

points: 0

Single

solenoid

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

HEND (home return complete

signal)/

SV (servo ON output signal) *3

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

-/

(RES (reset signal))

ST1 (forward end movement

signal)

(-)

ST0 (backward end movement

signal)

Standard

movement
between 2

points: 0

Double

solenoid

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

HEND (home return complete

signal)/

SV (servo ON output signal) *3

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

SPDC (travel speed switching

signal)

(RES (reset signal))

-/

*STP (pause signal)

ST0 (backward end movement

signal)

Change travel

speed: 1

Single

solenoid

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

HEND (home return complete

signal)/

SV (servo ON output signal) *3

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

SPDC (travel speed switching

signal)

(RES (reset signal))

ST1 (forward end movement

signal)

(-)

ST0 (backward end movement

signal)

Change travel

speed: 1

Double

solenoid

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

HEND (home return complete

signal)/

SV (servo ON output signal) *3

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

CN1 (target position switching

signal)

(RES (reset signal))

-/

*STP (pause signal)

ST0 (backward end movement

signal)

Position

data change: 2

Single

solenoid

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

HEND (home return complete

signal)/

SV (servo ON output signal) *3

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

CN1 (target position switching

signal)

(RES (reset signal))

ST1 (forward end movement

signal)

(-)

ST0 (backward end movement

signal)

Position

data change: 2

Double

solenoid

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

HEND (home return complete

signal)/

SV (servo ON output signal) *3

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

-/

(RES (reset signal))

-/

ST1 (forward end movement

signal)

ST0 (movement signal 1)

Movement by 2
inputs among 3

points: 3

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

LS2 (intermediate position

detection signal)/

PE2 (intermediate positioning

complete signal)*2

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

ST2 (position movement 2)

(RES (reset signal))

ST1 (forward end movement

signal)

(-)

ST0 (backward end movement

signal)

Movement by 3
inputs among 3

points: 4

Double

solenoid

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

LS2 (intermediate position

detection signal)/

PE2 (intermediate positioning

complete signal)*2

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

Input

-/

SON (servo ON signal) *1

-/

(RES (reset signal))

-/

*STP (pause signal)

ASTR (continuous back-and-

forth operation signal)

Continuous

back-and-forth

operation: 5

Output

*ALM (alarm output signal)/

SV (servo ON output signal) *3

HEND (home return complete

signal)/

SV (servo ON output signal) *3

LS1 (forward end position

detection signal)/

PE1 (forward end positioning

complete signal)*2

LS0 (backward end position

detection signal)/

PE0 (backward positioning

complete signal)*2

The signal name in parentheses indicates the signal state before home return.

*1

If the default I/O setting for servo control is set to "Control", the SON signal applies.

*2

If the default I/O setting for output signal type is set to "Limit Switch", LS is applied. If it is set to "Position
End", PE is applied.

*3

When "SV" is selected by the default I/O setting for output selection. In this case, the SV signal applies.
Either OUT2 or OUT3 can be set depending on the operation parameter and operation mode.