64

5. Operation of CON Controllers

5.6.4

Clearing Position Data, Clearing All Position Data

(1) Clearing position data

Position data of the selected position number can be cleared. The position becomes unregistered
and an "*" (asterisk) is shown in the fields.

1) Clear (Opration to return a desired position data number to an unregistered condition.)

Example Clear data of position data No. 1.

No.

Operation

Screen Remarks

1

Touch [Edit Position].

2

If the password is not "0000,"
the password screen appears.
Input a password.

The default password is
"0000."

3

The position data table screen
appears.

4

Touch [

n] and [p] to display the

table showing the position
number you want to set.

Position data fields in which no
data is registered yet contain an
"*" (asterisk).

5

Next, touch No. "001" of
position No. 1.

6 Touch

[Clear].