6. Operation of SEP

Controllers

[3] Examples of position setting operations

Respective operations are explained by giving specific examples.

1) Setting of position, speed, acceleration and deceleration

An example of operation mode 0 (standard) is explained.
Set positions to move the actuator back and forth between 10.0 mm and 100.0 mm.

Forward end position: 100.0 mm, backward end position: 10.0 mm, back-and-forth speed:
50 mm/sec, back-and-forth acceleration: 0.3 G, back-and-forth deceleration: 0.3 G

No.

Operation

Screen Remarks

1

On the SEP menu screen:
Touch [Pos.Edit].

2

If the password is other than
"0000," the password input
screen appears.

Input a password.

You can set a password for
position specification from
"Position edit password" on the
parameter edit screen.

3

Set the position, acceleration
and deceleration relating to the
backward end position.

Touch [Backward Position].

Touch [Menu] to return to the
SEP menu screen.

4

Touch the value in Position.
The numeric keypad appears.
Touch [1] and [0], and
touch [ENT].

Touch [Menu] to return to the
position setting screen.

5

10.00 is shown in Position.

Touch [Menu] to return to the
position setting screen.