IAI America CON-PG User Manual

Page 34

Advertising
background image

28

5. Operation of CON Controllers

Models other than SCON-CA, PCON-CA, ERC3
IO monitor screen

Touching [MoniMain] switches to the main monitor
display.
Touching [DataMoni] changes the display to one
showing only the current position, etc.
Touching Axis No. switches to the axis selection
screen.

x Input

The status of each input port is shown. ON is lit. OFF is unlit.

x Output

The status of each output port is shown. ON is lit. OFF is unlit.

Models other than SCON-CA, PCON-CA, ERC3
Data monitor screen

Touching [MoniMain] switches to the main monitor
display
Touching [IOMoni] changes the display to one
showing only I/Os.
Touching Axis No. switches to the axis selection
screen.

The current position is shown.

The speed is shown.

The pulse count is shown. Touching [Pulse Count] displays the pulse count. (It’ll
be shown in the pulse-train control controller mode such as PCON-PL/PC.)

The command value of electrical current is shown as a percentage of the rated
current.

The command value of electrical current is shown. Touch [Current] to display the
command value.

The applicable alarm code is shown.

The servo ON status is shown. ON is lit. OFF is unlit.

The home return status is shown. Lit, if home return has completed.

The voltage of the control power supply is shown.

The voltage of the motor power supply is shown.

The PCB temperature is shown.

Touch [Current] to display [Current Rate].
Touch [Current Rate] to display [Current]

x Position

The current position is shown.

x Velocity

The speed is shown.

x Pulse count

The pulse count is shown. Touching [Pulse Count] displays the pulse count. (The pulse
count is shown in the pulse-train control mode.)

x Current Rate

The command value of electrical current is shown as a percentage of the rated current.

x Current

The command value of electrical current is shown. Touch [Current Rate] to display the
command value.

x AlarmCode

The applicable alarm code is shown.

x Servo

The servo ON status is shown. ON is lit. OFF is unlit.

x Home

The home return status is shown. Lit, if home return has completed.

x ControlVoltage

The voltage of the control power supply is shown.

x MotorVoltage

The voltage of the motor power supply is shown.

x PCB Temperature The PCB temperature is shown.

Advertising