105

6. Operation of SEP

Controllers

Touching a desired position displays the screen for setting the target position/speed for the position
you have touched.
Set the position, speed, push power, push band, acceleration and deceleration.

Touch [Menu] to return to the SEP menu screen.

You can perform jog operation on this setting screen.

[1] Position

data

Set position data with which to operate the actuator.

Position data

[1] [2] [3] [4] [5] [6] [7]

Position

Data

Position

[mm]

Velocity

[mm/s]

Accelerate

[G]

Decelerate

[G]

PushPower

[%]

PushBand

[mm]

Ecology

[1]

Forward

Position

200.00 50.00 0.1

0.1

70

1.00 Valid

[2]

Backward

Position

0.00

50.00

0.1 0.1 0 0 Valid

[3]

Midway

Position

100.00

50.00

0.1 0.1 0 0 Valid

[1] Position (mm)--- Set the position to move the actuator to.

The positions must satisfy the following relationships: Backward position <
Midway position < Forward position

Setting position

Operation pattern

Move

Forward

Position

Backward

Position

Intermediat

e Position

Standard movement
between 2 points: 0

Movement between two points

{

{

Change travel speed: 1

Movement between two points

{

{

Position data change: 2

Movement between two points

{

{

Movement by 2 inputs
among 3 points: 3

Movement among three points

{

{

{

Movement by 3 inputs
among 3 points: 4

Movement among three points

{

{

{

Continuous back-and-forth
operation: 5

Movement between two points

{

{

[2] Velocity [mm/s]--- Set the actuator speed.
[3] Accelerate [G] --- Set the actuator acceleration.

The input range permits entry of values greater than what is specified in the
catalog. Refer to the catalog or operation manual of your actuator.

Forward end
position

Midway position

Backward
end position

Actuator

Motor

Advertising