IAI America CON-PG User Manual

Page 173

Advertising
background image

167

7. Operation of MEC Controllers

[1] Example of initial setting operation

The operation is explained using specific examples.

Example of stopping at 2 points

Set as follows.

No. Operation

Screen

Remarks

1

Touch [Initial set] on the MEC
menu screen.

2

If the password is not “0000,” the
password entry screen appears.
Enter the password, and then
touch [

€].

The password is “5119” (factory
setting). A desired password can
be set using the “system
password” parameter accessible
from the maintenance menu.

3

x Touch and select either [Two

Point] or [Three Point] based on
the number of positioning points.

x To perform positioning operation,

select [Pushing None]. To
perform push-motion operation,
select [Pushing].

x In the case of positioning to the

intermediate position in the 3-
point stop pattern, select
[Both OFF] or [Both ON] for the
ST0 and ST1 input signals, and
then touch [OK].

Stopping at 2 points

Stopping at 3 points

Touch [Menu] to return to the first
MEC menu screen.

(Reference)
Factory setting
Stop position: [Two Point]
Push function: [Pushing None]
Intermediate point specification
method: [Both ON]

4

Touch [Yes]

To make the specified items
effective, you must restart the
controller. The settings you have
made will not be reflected until the
controller is restarted.
Touch [No] to return to the
previous screen.

5

Advertising