6. Operation of SEP

Controllers

[Statuses of position detection output signals when the push function is not used]
Even when the servo is turned off, as long as the actuator is positioned within the positioning band
(parameter No. 1) the start point detection signal (LS0), end point detection signal (LS1) or
intermediate point detection signal (LS2) will turn ON according to the applicable position, just like
when a sensor is used. Accordingly, the position detection signal that has turned ON will remain ON
after completion of positioning unless the actuator moves.

[Status of position complete signals when the push function is used]
In push-motion operation, the servo does not turn off automatically while the actuator is pushing the
load.
If the actuator has missed the load, the servo turns off automatically.
Once the servo turns off, a position complete status is lost. Accordingly, the push complete signal 0
(PE0), push complete signal 1 (PE1) and push complete signal 2 (PE2) will all turn OFF regardless of
the stop position.

No holding torque is applied in the auto servo OFF mode. Since the actuator will move in this condition
if an external force is applied, pay due attention to contact and safety when setting any operation
involving auto servo OFF.

To change the travel speed for operation pattern (PIO pattern) 1, set the position at which to change
the speed, and the new speed, in addition to the position data.

Position setting screen

Speed Chg Pos

Position

Data

[8]

Change position [mm]

[9]

Change speed [mm]

[0] Forward Position

60.00

30.00

[1] Backward Position

40.00

30.00

[8] Speed Chg Pos --- Set the position at which to switch the speed while the actuator is moving to

the forward end position or backward end position.

[9] Speed Chg Vel ---

Set the speed to change to.

To change the position data for operation pattern (PIO pattern) 2, set the new position data for
forward end or backward end, in addition to the current position data for forward end position or
backward end position.
x If CN1 (operation switching signal) is OFF, the position data for forward end position becomes [1]:

Forward end position.
If the signal is ON, the position data becomes [3]: Forward end position.

x If CN1 (operation switching signal) is OFF, the position data for backward end position becomes

[0]: Backward end position.
If the signal is ON, the position data becomes [2]: Backward end position.

Position

Data

Position Velocity

Accelerate Decelerate PushPower

PushBand Ecology

[0]: Backward Position

0.00

50.00

0.1

0.1

0

0

Valid

[1]: Forward Position

200.00

50.00

0.1

0.1

70

1.00

Valid

[2]: Backward Position

10.00

50.00

0.1

0.1

0

0

Valid

[3]: Forward Position

100.00

50.00

0.1

0.1

60

1.00

Valid