5. Operation of CON Controllers

(1) Basic

operation

Touch [

n] to return to the previous screen.

Touch [

p] to move to the next screen.

Touch [Specify No] and enter a desired user parameter number, and the screen showing the user
parameter you want to set will appear.

In this example, soft limit+ is set.

Touch Soft limit+, and the numeric keypad will appear. Enter a
value and then touch [ENT] on the numeric keypad.

Touching [Menu1] opens a confirmation screen with a message asking if you want to restart the
controller.

Touch [Yes].

Touch [No] to return to the user parameter screen without
restarting the controller or reflecting the parameter you have set.
To reflect the parameter you have set, you must restart the
controller.

Caution: If the controller is not restarted, the parameter that has been rewritten does not translate to

the intended action.
The parameter will become effective once the controller is restarted or power is
reconnected.