184

7. Operation of MEC Controllers

4) Setting for push-motion operation (push force, push band)

An example of stopping at 2 points is explained.
In this example, push-motion operation is performed at the start point.

Push force: 50%, Push band: 5.0 mm

No. Operation

Screen

Remarks

1

Touch [Pos. Edit] on the MEC
menu screen.

2

If the password is not “0000,” the
password entry screen appears.
Enter the password.

A desired position setting
password can be set in the
“position data edit password” field
of the parameter edit screen.

3

Touch the value field of position.
When the numeric keypad is
displayed, touch [1], [0], and then
[ENT].

Touch [Starting Point].

Touch [Menu] to return to the MEC
menu screen.

4

Touch the value field of
[PushPower].
When the numeric keypad is
displayed, touch [5], [0], and then
[ENT].

Touch [Menu] to return to the
position setting screen

5

“50” is shown in the push power
field.

Touch [Menu] to return to the
position setting screen

6

Touch the value field of
[PushBand].

When the numeric keypad is
displayed, touch [5] and then
[ENT].

Touch [Menu] to return to the
position setting screen