151

6. Operation of SEP

Controllers

The settings of operation pattern 5 (continuous back-and-forth operation) vary partially from other
operation patterns.

x Start, Stop:

Continuous operation stops once the operation test screen appears.
Touching [Start] causes the actuator to move back and forth continuously at the
speed set by the override parameter.
The text on the switch changes to [Stop].
Touching [Stop] stops the actuator.

x Reset:

Touching [Reset] resets the back-and-forth counter to 0.

Continuous operation resumes once the operation test screen closes.

The current axis position is indicated.
The axis speed is indicated.
The electric current of the axis is
indicated by a percentage of the rating.
The number of back-and-forth
movements of the axis is indicated.